Editorial on “Determination of the accuracy of navigated kinematic unicompartmental knee arthroplasty: a 2-year follow-up”
Editorial

Editorial on “Determination of the accuracy of navigated kinematic unicompartmental knee arthroplasty: a 2-year follow-up”

Alexander H. Jinnah1, Michael Maggitti2, Riyaz H. Jinnah1,2

1Department of Orthopaedic Surgery, Wake Forest School of Medicine, Winston-Salem, NC, USA; 2Department of Orthopaedic Surgery, Southeastern Regional Medical Center, Lumberton, NC, USA

Correspondence to: Alexander H. Jinnah. Department of Orthopaedic Surgery, Wake Forest School of Medicine, 1 Medical Center Blvd, Winston-Salem, NC 27157, USA. Email: ajinnah@wakehealth.edu.

Comment on: Grant AL, Doma KD, Hazratwala K. Determination of the accuracy of navigated kinematic unicompartmental knee arthroplasty: a 2-year follow-up. J Arthroplasty 2017;32:1443-52.


Received: 06 November 2017; Accepted: 26 November 2017; Published: 29 November 2017.

doi: 10.21037/aoj.2017.11.02


The article entitled “Determination of the accuracy of navigated kinematic unicompartmental knee arthroplasty: a 2-year follow-up” (1) published in the Journal of Arthroplasty was reviewed in detail. We would like to commend the authors on taking on such an important topic. This investigation retrospectively reviewed prospective data collected over a 4-year period on consecutive patients that underwent minimally invasive unicompartmental knee arthroplasty (UKA) with the Stryker (Mahwah, NJ, USA) Triathlon partial knee arthroplasty (PKA) prosthesis with the use of the Stryker precision computer navigation (PCN) system. The primary outcome goal of the procedure was to restore the pre-operative stress value as the final alignment of the knee. Secondary outcomes included Western Ontario and McMaster Universities (WOMAC), Knee Society Score (KSS) and range of motion (ROM) pre-operatively, 1 year post-operatively, and 2 years post-operatively. The authors found there to be no significant differences between the stress value and the postoperative alignment, suggesting that their surgical technique allowed them to recreate the pre-disease alignment. Furthermore, they found there to be a significant improvement in the WOMAC and KSS, but no changes were seen in ROM.

The importance of this topic stems from variability in surgical technique being one of the largest remaining barriers to the re-creation of an anatomic and functional joint in the modern era of arthroplasty. Variability to a certain degree is important, because no two patients are alike, and decisions must be made pre-operatively, and intra-operatively in order to determine the best option for the patient. However; physicians have used imaging modalities and tools to attempt to move forward in all aspects of medicine. This is where the introduction of technology into the operating room can help. The use of navigation in this investigation showed that reproducing pre-planned limb alignment post-operatively is possible. Furthermore, the navigation system allowed the authors to do this in a minimally invasive fashion.

Computer assistance in joint replacement began in 1992 with the introduction of the ROBODOC (THINKSurgical, originally by Integrated Surgical Systems) to improve acetabular cup placement during total hip arthroplasties. This was an active robotic system, which means no surgical assistance is needed once the exposure is completed. However, this system was discontinued due to technical complications (2). In the early 2000’s robotic assisted devices were introduced (3). These devices combined the skills of the surgeon and the abilities of the robotic system in order to produce the ideal implant position to enable excellent tracking and dynamic ligament balancing. Improved accuracy of component placement was demonstrated with early results with UKA. Bell et al. (4) recently published level 1 data demonstrating this in all three planes of alignment when compared to a conventional manual UKA. This is in accordance with earlier studies investigating this same topic (5-7). In addition to the increased accuracy of component placement, others have demonstrated accurate ligament balancing with the assistance of this technology (8). The use of a navigation system to re-create the pre-disease alignment of the joint demonstrates a significant step forward. However, the data in larger comparative trials using navigation has been conflicting when comparing alignment to conventional methods (9,10). Navigation systems assist with preoperative planning, simulation, and intraoperative guidance (3). The main difference between the navigation systems and the robotic assisted systems stems from the fact that the navigation system cannot mitigate the effects of mechanical human error. The robotic assisted systems allow the surgeons to have autonomy during the procedure, but will not allow bone cutting outside the pre-planned area; whereas the navigation systems inform you where cuts need to be made in order to achieve the planned component placement, but no safeguards are in place to assure this is done to the exact specifications. Furthermore, while navigation is very useful in obtaining static ligament balancing; robotic assisted systems allow dynamic balancing to be achieved.

This investigation certainly adds to the literature and demonstrates a significant step forward. Further comparative studies should be performed to identify if in fact this navigation system produces superior results when compared to other techniques. However, due to the variability in the literature it is our opinion that the optimal way of achieving accurate placement of components and planned limb alignment in UKA is through the use of a robotic assisted system with haptic feedback. Although, it is important to note that long term results have not yet demonstrated any difference in patient reported outcomes when compared to conventional manual techniques.


Acknowledgments

Funding: None.


Footnote

Provenance and Peer Review: This article was commissioned and reviewed by the Executive Editor-in-Chief, Dongquan Shi, MD, PhD (Department of Sports Medicine and Adult Reconstruction, Drum Tower Hospital, Medical School, Nanjing University, Nanjing, China).

Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at http://dx.doi.org/10.21037/aoj.2017.11.02). The authors have no conflicts of interest to declare.

Ethical Statement: The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.

Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.


References

  1. Grant AL, Doma KD, Hazratwala K. Determination of the accuracy of navigated kinematic unicompartmental knee arthroplasty: a 2-year follow-up. J Arthroplasty 2017;32:1443-52. [Crossref] [PubMed]
  2. Lang JE, Mannava S, Floyd AJ, et al. Robotic systems in orthopaedic surgery. J Bone Joint Surg Br 2011;93:1296-9. [Crossref] [PubMed]
  3. Jinnah AH, Multani A, Plate JF, et al. Implementation of robotics in total joint arthroplasty. Robotic Surgery: Research and Reviews 2015;2:73-9. [Crossref]
  4. Bell SW, Anthony I, Jones B, et al. Improved accuracy of component positioning with robotic-assisted unicompartmental knee arthroplasty: data from a prospective, randomized controlled study. J Bone Joint Surg Am 2016;98:627-35. [Crossref] [PubMed]
  5. Mofidi A, Plate JF, Lu B, et al. Assessment of accuracy of robotically assisted unicompartmental arthroplasty. Knee Surg Sports Traumatol Arthrosc 2014;22:1918-25. [Crossref] [PubMed]
  6. Lonner JH, John TK, Conditt MA. Robotic arm-assisted UKA improves tibial component alignment: a pilot study. Clin Orthop Relat Res 2010;468:141-6. [Crossref] [PubMed]
  7. Weber P, Crispin A, Schmidutz F, et al. Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 2013;21:2453-61. [Crossref] [PubMed]
  8. Plate JF, Mofidi A, Mannava S, et al. Achieving accurate ligament balancing using robotic-assisted unicompartmental knee arthroplasty. Adv Orthop 2013;2013:837167.
  9. Valenzuela GA, Jacobson NA, Geist DJ, et al. Implant and limb alignment outcomes for conventional and navigated unicompartmental knee arthroplasty. J Arthroplasty 2013;28:463-8. [Crossref] [PubMed]
  10. Jung KA, Kim SJ, Lee SC, et al. Accuracy of implantation during computer-assisted minimally invasive Oxford unicompartmental knee arthroplasty: a comparison with a conventional instrumented technique. Knee 2010;17:387-91. [Crossref] [PubMed]
doi: 10.21037/aoj.2017.11.02
Cite this article as: Jinnah AH, Maggitti M, Jinnah RH. Editorial on “Determination of the accuracy of navigated kinematic unicompartmental knee arthroplasty: a 2-year follow-up”. Ann Joint 2017;2:74.